Street canyon ventilation and airborne pollution dispersion: 2-D versus 3-D CFD simulations

[thumbnail of manuscript preparef for SCSR1 revised002 - clean (1).pdf]
Preview
Text - Accepted Version
· Available under License Creative Commons Attribution Non-commercial No Derivatives.
· Please see our End User Agreement before downloading.
| Preview

Please see our End User Agreement.

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Mei, S.-J., Luo, Z. orcid id iconORCID: https://orcid.org/0000-0002-2082-3958, Zhao, F.-Y. and Wang, H.-Q. (2019) Street canyon ventilation and airborne pollution dispersion: 2-D versus 3-D CFD simulations. Sustainable Cities and Society, 50. 101700. ISSN 2210-6707 doi: 10.1016/j.scs.2019.101700

Abstract/Summary

Urban ventilation is important for building a healthy urban living environment. 2-D CFD simulation has been used widely for street canyon ventilation due to its computational efficiency, but its applicability for a 3-D simulation has never been studied. This paper tried to answer the question: if and under what conditions, the widely-adopted 2-D CFD simulations on street canyon ventilation can represent real 3-D scenarios? 3-D simulations on street canyons with various street lengths and corresponding 2-D simulations are carried out with RNG k-ε model. Our study identified two important ventilation mechanism for controlling ventilation and dispersion in a 3-D street canyon, i.e., canyon vortex on the canyon top and the corner vortices at the street ends. The relative importance of these two driving forces will change with the street length/street width ratio (B/W). For isolated street canyon, when B/W is higher than 20 (for H/W=1) and 70 (H/W=2), the street canyon ventilation will be dominated by canyon vortex, and 3-D street canyon ventilation could be simplified as a 2-D case. For multiple street canyon, the threshold of B/W will become 20 when H/W=1, and 50 when H/W=2. The findings in this study could improve our approaches for simulating urban ventilation.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/84719
Identification Number/DOI 10.1016/j.scs.2019.101700
Refereed Yes
Divisions Interdisciplinary Research Centres (IDRCs) > Walker Institute
Science > School of the Built Environment > Urban Living group
Science > School of the Built Environment > Energy and Environmental Engineering group