Search from over 60,000 research works

Advanced Search

Performance statistics of a head-operated force-reflecting rehabilitation robot system

Full text not archived in this repository.
Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Chen, S., Rahman, T. and Harwin, W. S. orcid id iconORCID: https://orcid.org/0000-0002-3928-3381 (1998) Performance statistics of a head-operated force-reflecting rehabilitation robot system. IEEE Transactions on Rehabilitation Engineering, 6 (4). pp. 406-414. ISSN 1063-6528 doi: 10.1109/86.736155

Abstract/Summary

Researchers in the rehabilitation engineering community have been designing and developing a variety of passive/active devices to help persons with limited upper extremity function to perform essential daily manipulations. Devices range from low-end tools such as head/mouth sticks to sophisticated robots using vision and speech input. While almost all of the high-end equipment developed to date relies on visual feedback alone to guide the user providing no tactile or proprioceptive cues, the “low-tech” head/mouth sticks deliver better “feel” because of the inherent force feedback through physical contact with the user's body. However, the disadvantage of a conventional head/mouth stick is that it can only function in a limited workspace and the performance is limited by the user's strength. It therefore seems reasonable to attempt to develop a system that exploits the advantages of the two approaches: the power and flexibility of robotic systems with the sensory feedback of a headstick. The system presented in this paper reflects the design philosophy stated above. This system contains a pair of master-slave robots with the master being operated by the user's head and the slave acting as a telestick. Described in this paper are the design, control strategies, implementation and performance evaluation of the head-controlled force-reflecting telestick system.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/19022
Item Type Article
Refereed Yes
Divisions Life Sciences > School of Biological Sciences > Department of Bio-Engineering
Uncontrolled Keywords Fitt's law, control strategies, conventional head/mouth stick, force feedback control, head-operated force-reflecting rehabilitation robot system, headstick, high-end equipment, inherent force feedback, master-slave robots, passive/active devices, performance statistics, sensory feedback, telestick, visual feedback
Publisher IEEE
Download/View statistics View download statistics for this item

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar