Yao, R. orcid id iconORCID: https://orcid.org/0000-0003-4269-7224, Ding, Y., Li, B. and Tan, Y. (2010) Part load operation coefficient of air-conditioning system of public building. Energy and Buildings, 42 (10). pp. 1902-1907. ISSN 0378-7788 doi: 10.1016/j.enbuild.2010.05.026

Abstract/Summary

IPLV overall coefficient, presented by Air-Conditioning and Refrigeration Institute (ARI) of America, shows running/operation status of air-conditioning system host only. For overall operation coefficient, logical solution has not been developed, to reflect the whole air-conditioning system under part load. In this research undertaking, the running time proportions of air-conditioning systems under part load have been obtained through analysis on energy consumption data during practical operation in all public buildings in Chongqing. This was achieved by using analysis methods, based on the statistical energy consumption data distribution of public buildings month-by-month. Comparing with the weight number of IPLV, part load operation coefficient of air-conditioning system, based on this research, does not only show the status of system refrigerating host, but also reflects and calculate energy efficiency of the whole air-conditioning system. The coefficient results from the processing and analyzing of practical running data, shows the practical running status of area and building type (actual and objective) – not clear. The method is different from model analysis which gets IPLV weight number, in the sense that this method of coefficient results in both four equal proportions and also part load operation coefficient of air-conditioning system under any load rate as necessary.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/16791
Identification Number/DOI 10.1016/j.enbuild.2010.05.026
Refereed Yes
Divisions Science > School of the Built Environment > Energy and Environmental Engineering group
Publisher Elsevier
Download/View statistics View download statistics for this item

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar