Search from over 60,000 research works

Advanced Search

Eliminating resistance measurement error due to thermoelectric effects in micro four-point probe measurements

[thumbnail of Open Access]
Preview
244501_1_5.0244261.pdf - Published Version (1MB) | Preview
Available under license: Creative Commons Attribution
Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Lamba, N. orcid id iconORCID: https://orcid.org/0000-0003-1337-9083, Guralnik, B. orcid id iconORCID: https://orcid.org/0000-0003-3095-3868, Prado-Gonjal, J., Powell, A. V. orcid id iconORCID: https://orcid.org/0000-0002-9650-1568, Pryds, N. orcid id iconORCID: https://orcid.org/0000-0002-5718-7924, Hansen, O. orcid id iconORCID: https://orcid.org/0000-0002-6090-8323, Petersen, D. H. orcid id iconORCID: https://orcid.org/0000-0002-9309-4186 and Beltrán-Pitarch, B. orcid id iconORCID: https://orcid.org/0000-0002-4596-9582 (2024) Eliminating resistance measurement error due to thermoelectric effects in micro four-point probe measurements. Journal of Applied Physics, 136 (24). 244501. ISSN 1089-7550 doi: 10.1063/5.0244261

Abstract/Summary

The micro four-point probe (M4PP) technique has become a well-established method for characterizing the electrical properties of materials. However, extra attention must be paid when measuring the resistivity of thermoelectric materials due to the possibility of an additional Seebeck voltage. This issue vanishes when measuring at a sufficiently high frequency, but the threshold frequency is substantial due to the small separation between the pins of the probes. Typical M4PP measurements are far from reaching this frequency, and their accuracy on thermoelectric materials is severely compromised. In this work, we explain the experimental conditions needed to measure reliably the electrical conductivity of thermoelectric materials and present a new method for measuring this property that reduces the frequency requirements by two orders of magnitude. The method is proven using two skutterudites and bismuth telluride material. It is also found that the resistance overestimation in the bismuth telluride sample is larger than that in the skutterudites due to its superior thermoelectric properties; the overestimate reaching 35%. The advances reported here enable the M4PP technique to be used for the measurement of the electrical conductivity of thermoelectric materials.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/120043
Item Type Article
Refereed Yes
Divisions Life Sciences > School of Chemistry, Food and Pharmacy > Department of Chemistry
Publisher AIP Publishing
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar