An experimental investigation of the flow and comfort parameters for under-floor, confluent jets and mixing ventilation systems in an open-plan office

Full text not archived in this repository.

Please see our End User Agreement.

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Arghand, T., Karimipanah, T. orcid id iconORCID: https://orcid.org/0000-0002-9392-424X, Awbi, H. B. orcid id iconORCID: https://orcid.org/0000-0003-0201-3801, Cehlin, M., Larsson, U. and Linden, E. (2015) An experimental investigation of the flow and comfort parameters for under-floor, confluent jets and mixing ventilation systems in an open-plan office. Building and Environment, 92. pp. 48-60. ISSN 1873-684X doi: 10.1016/j.buildenv.2015.04.019

Abstract/Summary

There is a new trend to convert the workplaces from individual office rooms to open offices for motivating money saving and better communication. With such a shift the ability of existing ventilation systems in meeting the new requirements is a challenging question for researchers. The available options could have an impact on workers' health in terms of providing acceptable levels of thermal comfort and indoor air quality. Thus, this experimental investigation focuses on the performances of three different air distribution systems in an open-plan office space. The investigated systems were: mixing ventilation with ceiling-mounted inlets, confluent jets ventilation and underfloor air distribution with straight and curved vanes. Although this represents a small part of our more extensive experimental investigation, the results show that all the purposed stratified ventilation systems (CJV and UFAD) were more or less behaving as mixing systems with some tendency for displacement effects. Nevertheless, it is known that the mixing systems have a stable flow pattern but has the disadvantage of mixing contaminated air with the fresh supplied air which may produce lower performance and in worst cases occupants' illness. For the open-plan office we studied here, it will be shown that the new systems are capable of performing better than the conventional mixing systems. As expected, the higher air exchange efficiency in combination with lower local mean age of air for corner-mounted CJV and floor-mounted UFAD grills systems indicates that these systems are suitable for open-plan offices and are to be favored over conventional mixing systems.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/114577
Identification Number/DOI 10.1016/j.buildenv.2015.04.019
Refereed Yes
Divisions Science > School of the Built Environment > Construction Management and Engineering
Publisher Elsevier
Download/View statistics View download statistics for this item

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar