A new framework for using weather‐sensitive surplus power reserves in critical infrastructure

[thumbnail of Open Access]
Preview
Text (Open Access) - Published Version
· Available under License Creative Commons Attribution.
· Please see our End User Agreement before downloading.
| Preview
Available under license: Creative Commons Attribution

Please see our End User Agreement.

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Fallon, J. orcid id iconORCID: https://orcid.org/0000-0002-6321-7456, Brayshaw, D. orcid id iconORCID: https://orcid.org/0000-0002-3927-4362, Methven, J. orcid id iconORCID: https://orcid.org/0000-0002-7636-6872, Jensen, K. and Krug, L. (2023) A new framework for using weather‐sensitive surplus power reserves in critical infrastructure. Meteorological Applications, 30 (6). e2158. ISSN 1469-8080 doi: 10.1002/met.2158

Abstract/Summary

Reserve power systems are widely used to provide power to critical infrastructure systems in the event of power outages. The reserve power system may be subject to regulation, typically focussing on a strict operational time commitment, but the energy involved in supplying reserve power may be highly variable. For example, if heating or cooling is involved, energy consumption may be strongly influenced by prevailing weather conditions and seasonality. Replacing legacy assets (often diesel generators) with modern technologies could offer potential benefits and services back to the wider electricity system when not in use, therefore supporting a transition to low-carbon energy networks. Drawing on the Great Britain telecommunications systems as an example, this paper demonstrates that meteorological reanalyses can be used to evaluate capacity requirements to maintain the regulated target of 5-days operational reserve. Across three case-study regions with diverse weather sensitivities, infrastructure with cooling-driven electricity demand is shown to increase energy consumption during summer, thus determining the overall capacity of the reserve required and the availability of ‘surplus’ capacity. Lower risk tolerance is shown to lead to a substantial cost increase in terms of capacity required but also enhanced opportunities for surplus capacity. The use of meteorological forecast information is shown to facilitate increased surplus capacity. Availability of surplus capacity is compared to a measure of supply–stress (demand-net-wind) on the wider energy network. For infrastructure with cooling-driven demand (typical of most UK telecommunication assets), it is shown that surplus availability peaks during periods of supply–stress, offering the greatest potential benefit to the national electricity grid.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/114191
Identification Number/DOI 10.1002/met.2158
Refereed Yes
Divisions Interdisciplinary centres and themes > Energy Research
Science > School of Mathematical, Physical and Computational Sciences > Department of Meteorology
Publisher Royal Meteorological Society
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record