Search from over 60,000 research works

Advanced Search

X-Ray tomography-based microstructure representation in the Snow Microwave Radiative Transfer model

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Sandells, M., Lowe, H., Picard, G., Dumont, M., Essery, R., Floury, N., Kontu, A., Lemmetyinen, J., Maslanka, W. orcid id iconORCID: https://orcid.org/0000-0002-1777-733X, Morin, S., Wiesmann, A. and Matzler, C. (2022) X-Ray tomography-based microstructure representation in the Snow Microwave Radiative Transfer model. IEEE Transactions on Geoscience and Remote Sensing, 60. ISSN 0196-2892 doi: 10.1109/TGRS.2021.3086412

Abstract/Summary

The modular Snow Microwave Radiative Transfer (SMRT) model simulates microwave scattering behavior in snow via different selectable theories and snow microstructure representations, which is well suited to intercomparisons analyses. Here, five microstructure models were parameterized from X-ray tomography and thin-section images of snow samples and evaluated with SMRT. Three field experiments provided observations of scattering and absorption coefficients, brightness temperature, and/or backscatter with the increasing complexity of snowpack. These took place in Sodankylä, Finland, and Weissfluhjoch, Switzerland. Simulations of scattering and absorption coefficients agreed well with observations, with higher errors for snow with predominantly vertical structures. For simulation of brightness temperature, difficulty in retrieving stickiness with the Sticky Hard Sphere microstructure model resulted in relatively poor performance for two experiments, but good agreement for the third. Exponential microstructure gave generally good results, near to the best performing models for two field experiments. The Independent Sphere model gave intermediate results. New Teubner–Strey and Gaussian Random Field models demonstrated the advantages of SMRT over microwave models with restricted microstructural geometry. Relative model performance is assessed by the quality of the microstructure model fit to microcomputed tomography (CT) data and further improvements may be possible with different fitting techniques. Careful consideration of simulation stratigraphy is required in this new era of high resolution microstructure measurement as layers thinner than the wavelength introduce artificial scattering boundaries not seen by the instrument.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/101250
Item Type Article
Refereed Yes
Divisions Science > School of Archaeology, Geography and Environmental Science > Department of Geography and Environmental Science
Publisher IEEE Geoscience and Remote Sensing Society
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar