Search from over 60,000 research works

Advanced Search

Turbulent flow at 190 m height above London during 2006-2008: A climatology and the applicability of similarity theory

[thumbnail of Wood_etal_2010_BLMet.pdf]
Preview
Wood_etal_2010_BLMet.pdf - Updated Version (1MB) | Preview
Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Wood, C. R., Lacser, A., Barlow, J. F., Padhra, A., Belcher, S. E., Nemitz, E., Helfter, C., Famulari, D. and Grimmond, C.S.B. orcid id iconORCID: https://orcid.org/0000-0002-3166-9415 (2010) Turbulent flow at 190 m height above London during 2006-2008: A climatology and the applicability of similarity theory. Boundary-Layer Meteorology, 137 (1). pp. 77-96. ISSN 0006-8314 doi: 10.1007/s10546-010-9516-x

Abstract/Summary

Flow and turbulence above urban terrain is more complex than above rural terrain, due to the different momentum and heat transfer characteristics that are affected by the presence of buildings (e.g. pressure variations around buildings). The applicability of similarity theory (as developed over rural terrain) is tested using observations of flow from a sonic anemometer located at 190.3 m height in London, U.K. using about 6500 h of data. Turbulence statistics—dimensionless wind speed and temperature, standard deviations and correlation coefficients for momentum and heat transfer—were analysed in three ways. First, turbulence statistics were plotted as a function only of a local stability parameter z/Λ (where Λ is the local Obukhov length and z is the height above ground); the σ_i/u_* values (i = u, v, w) for neutral conditions are 2.3, 1.85 and 1.35 respectively, similar to canonical values. Second, analysis of urban mixed-layer formulations during daytime convective conditions over London was undertaken, showing that atmospheric turbulence at high altitude over large cities might not behave dissimilarly from that over rural terrain. Third, correlation coefficients for heat and momentum were analyzed with respect to local stability. The results give confidence in using the framework of local similarity for turbulence measured over London, and perhaps other cities. However, the following caveats for our data are worth noting: (i) the terrain is reasonably flat, (ii) building heights vary little over a large area, and (iii) the sensor height is above the mean roughness sublayer depth.

Altmetric Badge

Additional Information http://www.met.reading.ac.uk/bl_met/papers/Wood/
Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/5974
Item Type Article
Refereed Yes
Divisions Science > School of Mathematical, Physical and Computational Sciences > Department of Meteorology
Uncontrolled Keywords Mixed-layer - Similarity theory - Urban boundary layer - Urban meteorology - Urban turbulence
Additional Information http://www.met.reading.ac.uk/bl_met/papers/Wood/
Publisher Springer
Publisher Statement The original publication is available at www.springerlink.com
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record