Gardiner, T. D., Coleman, M. D., Innocenti, F., Tompkins, J., Connor, A., Garnsworthy, P. C., Moorby, J. M., Reynolds, C. K. ORCID: https://orcid.org/0000-0002-4152-1190, Waterhouse, A. and Wills, D.
(2015)
Determination of the absolute accuracy of UK chamber
facilities used in measuring methane emissions from livestock.
Measurement, 66.
pp. 272-279.
ISSN 0263-2241
doi: 10.1016/j.measurement.2015.02.029
Abstract/Summary
Respiration chambers are one of the primary sources of data on methane emissions from livestock. This paper describes the results from a coordinated set of chamber validation experiments which establishes the absolute accuracy of the methane emission rates measured by the chambers, and for the first time provides metrological traceability to international standards, assesses the impact of both analyser and chamber response times on measurement uncertainty and establishes direct comparability between measurements made across different facilities with a wide range of chamber designs. As a result of the validation exercise the estimated combined uncertainty associated with the overall capability across all facilities reduced from 25.7% (k = 2, 95% confidence) before the validation to 2.1% (k = 2, 95% confidence) when the validation results are applied to the facilities’ data.
Altmetric Badge
Item Type | Article |
URI | https://reading-clone.eprints-hosting.org/id/eprint/39634 |
Item Type | Article |
Refereed | Yes |
Divisions | Life Sciences > School of Agriculture, Policy and Development > Department of Animal Sciences > Animal, Dairy and Food Chain Sciences (ADFCS)- DO NOT USE |
Uncontrolled Keywords | Respiration chambers Methane emissions Livestock emissions Calibration Traceability |
Publisher | Elsevier |
Download/View statistics | View download statistics for this item |
Downloads
Downloads per month over past year
University Staff: Request a correction | Centaur Editors: Update this record