Wu, Y., Gan, G., Garcia Gonzalez, R., Verhoef, A. ORCID: https://orcid.org/0000-0002-9498-6696 and Vidale, P. L.
ORCID: https://orcid.org/0000-0002-1800-8460
(2011)
Prediction of the thermal performance of horizontal-coupled ground source heat exchangers.
International Journal of Low-Carbon Technologies, 6 (4).
pp. 261-269.
ISSN 1748-1317
doi: 10.1093/ijlct/ctr013
Abstract/Summary
The thermal performance of a horizontal-coupled ground-source heat pump system has been assessed both experimentally and numerically in a UK climate. A numerical simulation of thermal behaviour of the horizontal-coupled heat exchanger for combinations of different ambient air temperatures, wind speeds, refrigerant temperature and soil thermal properties was studied using a validated 2D transient model. The specific heat extraction by the heat exchanger increased with ambient temperature and soil thermal conductivity, however it decreased with increasing refrigerant temperature. The effect of wind speed was negligible.
Altmetric Badge
Item Type | Article |
URI | https://reading-clone.eprints-hosting.org/id/eprint/23394 |
Item Type | Article |
Refereed | Yes |
Divisions | Science > School of Archaeology, Geography and Environmental Science > Department of Geography and Environmental Science Science > School of Archaeology, Geography and Environmental Science > Earth Systems Science Interdisciplinary centres and themes > Soil Research Centre |
Publisher | Oxford University Press |
Download/View statistics | View download statistics for this item |
University Staff: Request a correction | Centaur Editors: Update this record