Search from over 60,000 research works

Advanced Search

Time in patterns: machine learning based blood glucose fluctuation pattern recognition for Type 1 diabetes management in continuous glucose monitoring

[thumbnail of Open Access]
Preview
PDF.pdf - Published Version (838kB) | Preview
Available under license: Creative Commons Attribution
Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Chan, N. B., Li, W. orcid id iconORCID: https://orcid.org/0000-0003-2878-3185, Aung, T., Bazuaye, E. and Montero, R. M. (2023) Time in patterns: machine learning based blood glucose fluctuation pattern recognition for Type 1 diabetes management in continuous glucose monitoring. JMIR AI, 2023 (2). e45450. ISSN 2817-1705 doi: 10.2196/45450

Abstract/Summary

Introduction. Continuous glucose monitoring (CGM) for diabetes combines non-invasive glucose biosensors, continuous monitoring, cloud and analytics to connect and simulate a hospital setting in a person’s home. CGM systems inspired analytics methods to measure glycemic variability yet existing glycemic variability analytics methods disregard glucose trends and patterns, hence they fail to capture entire temporal patterns nor provide granular insights of glucose fluctuations. Aim. To propose a machine learning-based framework for blood glucose fluctuation pattern recognition which enables a more comprehensive representation of glycemic variability profiles that could present detailed fluctuation information; be easily understood by clinicians; and to provide insights on patient groups based on time in blood fluctuation patterns. Methods. 1.5 million measurements from 126 patients in the UK with type 1 diabetes were collected, and prevalent blood fluctuation patterns were extracted using dynamic time warping. The patterns were further validated in 225 patients in US with type 1 diabetes. Hierarchical clustering was then applied on time in patterns to form four clusters of patients. Patient groups were compared through statistical analysis. Results. Six patterns depicting distinctive glucose levels and trends were found and validated. Based on which, four glycemic variability profiles of type 1 diabetes patients were found. They were significantly different in terms of glycemic statuses such as diabetes duration, HbA1c and time in range, and thus had different management needs. Conclusion. The proposed method can analytically extract existing blood fluctuation patterns in CGM data. Thus, time in patterns can capture a richer view of patients’ glycemic variability profile. Its conceptual resemblance with time in range along with rich blood fluctuation details makes it more scalable, accessible, and informative to clinicians.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/111564
Item Type Article
Refereed Yes
Divisions Interdisciplinary centres and themes > Health Innovation Partnership (HIP)
Henley Business School > Digitalisation, Marketing and Entrepreneurship
Publisher JMIR Publications
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar