A method for estimating scheduled and manual override heating behaviour and settings from measurements in low energy UK homes

[thumbnail of Full paper.pdf]
Preview
Text - Accepted Version
· Please see our End User Agreement before downloading.
| Preview

Please see our End User Agreement.

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Bruce-Konuah, A., Jones, R. V. orcid id iconORCID: https://orcid.org/0000-0002-2716-9872 and Fuertes, A. orcid id iconORCID: https://orcid.org/0000-0002-6224-1489 (2023) A method for estimating scheduled and manual override heating behaviour and settings from measurements in low energy UK homes. International Journal of Building Pathology and Adaptation, 41 (1). pp. 25-44. ISSN 2398-4708 doi: 10.1108/IJBPA-05-2021-0074

Abstract/Summary

Purpose The purpose of this paper is to present a methodology for estimating scheduled and manual override heating events and heating settings from indoor air temperature and gas use measurements in UK homes. Design/methodology/approach Living room air temperature and gas use data were measured in ten UK homes built to low energy standards. The temperature measurements are used to establish whether the central heating system is turned on or off and to estimate the heating setpoint used. The estimated heating periods are verified using the homes' average daily gas consumption profiles. Findings Using this method, the average number of heating periods per day was 2.2 (SD = 0.8) on weekdays and 2.7 (SD = 0.5) on weekends. The weekday mean heating duration was 8.8 h and for weekends, it was 9.8 h. Manual overrides of the settings occurred in all the dwellings and added an average of 2.4 h and 1.5 h to the heating duration on weekdays and weekends respectively. The mean estimated setpoint temperatures were 21.2 and 21.4°C on weekdays and weekends respectively. Research limitations/implications Manual overrides of heating behaviours have only previously been assessed by questionnaire survey. This paper demonstrates an alternative method to identifying these manual override events and responds to a key gap in the current body of research that little is currently reported on the frequency and duration of manual heating overrides in UK homes. Practical implications The results could be used to better inform the assumptions of space heating behaviour used in energy models in order to more accurately predict the space heating energy demands of dwellings. Originality/value Manual overrides of heating behaviours have only previously been assessed by questionnaire survey. This paper demonstrates an alternative method to identifying these manual override events and responds to a key gap in the current body of research that little is currently reported on the frequency and duration of manual heating overrides in UK homes.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/105820
Identification Number/DOI 10.1108/IJBPA-05-2021-0074
Refereed Yes
Divisions No Reading authors. Back catalogue items
Science > School of the Built Environment > Construction Management and Engineering
Science > School of the Built Environment > Energy and Environmental Engineering group
Science > School of the Built Environment > Organisation, People and Technology group
Publisher Emerald