Ultrahigh-throughput sample analysis using liquid atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry

[thumbnail of Open access]
Preview
Text (Open access) - Published Version
· Available under License Creative Commons Attribution.
· Please see our End User Agreement before downloading.
| Preview
Available under license: Creative Commons Attribution
[thumbnail of HTS mansucript - final - clean.pdf]
Text - Accepted Version
· Restricted to Repository staff only
Restricted to Repository staff only

Please see our End User Agreement.

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Krenkel, H., Brown, J., Richardson, K., Hoyes, E., Morris, M. and Cramer, R. orcid id iconORCID: https://orcid.org/0000-0002-8037-2511 (2022) Ultrahigh-throughput sample analysis using liquid atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry. Analytical Chemistry, 94 (10). pp. 4141-4145. ISSN 0003-2700 doi: 10.1021/acs.analchem.1c05614

Abstract/Summary

Mass spectrometry (MS) allows for automated analysis of complex samples at high resolution without the need for labeling/derivatization. Liquid atmospheric pressure matrix-assisted laser desorption/ionization (LAP-MALDI) enables rapid sample preparation and MS analysis using microtiter-plate formats and high-performing mass spectrometers. We present a step change in high-speed, large-scale MS sample analysis of peptides at 20 samples/s and an enzymatic assay at 40 samples/s, i.e., an order of magnitude faster than current MS platforms. LAP-MALDI requires only low amounts of sample volume (<2 μL), of which only a fraction (<1%) is typically consumed, and allows for multiplexing and high-speed MS/MS analysis, demonstrated at ∼10 samples/s. Its high ion signal stability and similarity to electrospray ionization enables CVs below 10% and the analysis of multiply charged peptide ions at these extreme speeds. LAP-MALDI MS fulfills the speed requirements for large-scale population diagnostics and compound screening with the potential of analyzing >1 million samples per day.

Altmetric Badge

Item Type Article
URI https://reading-clone.eprints-hosting.org/id/eprint/104028
Identification Number/DOI 10.1021/acs.analchem.1c05614
Refereed Yes
Divisions Life Sciences > School of Chemistry, Food and Pharmacy > Department of Chemistry
Publisher American Chemical Society
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record

Search Google Scholar